Descargar Imprimir esta página

Amsta AMCG90BM Manual De Instrucciones página 36

Publicidad

Idiomas disponibles

Idiomas disponibles

Regulator
LPG - NG, NG – LPG conversions;
Figure 6
Figura 6.4
This part is used in some countries or regions.
If the regulator is mounted on the product, do not
remove it and do not play with its adjustment.
This device is fixed to prevent any failures arising from
high gas pressure.
In case of conversion from LPG to NG, you are not
required to remove the part.
Figure 6.1
Remove the burner cover and burner as shown in the Figure 6.
Remove the injector by help of 7's socket screw driver as shown in
the Figure 6.1.
Fix the injector (D) you want to convert as shown in the Figure 6.2.
(see Table 1)
Put the burner in place again as shown in the Figure 6.3. Upon
completion of the conversion, then burn the burners in order and
remove the switch on the control panel and adjust the low flame
length by tightening or untightening the screw on the gas valve
(Figure 6.4 cock) or inside the valve shaft.
Figure 6.2
Figure 6.3
14

Publicidad

loading