BATTERY CHANGE
Battery discharge status is signalled by sev-
eral LED red flashes during transmission is in
progress. In case the transmitter is paired with
a controller, the battery discharge status is
displayed in the mobile application in the form
of a message. The transmitter signals the bat-
tery must be changed when its voltage drops
below the <2.1 V value. The signal is cancelled
only after the battery change.
1. Remove the button by means of a flat screw-
driver (Fig. 1).
2. By means of a screwdriver lever up the printed-
circuit board releasing the bottom latch and re-
move it from the base (Fig. 2).
3. Remove the battery from the latch (Fig. 3).
4. Press any button of the transmitter a few times
(to fully discharge).
5. Mount a new battery. Watch battery polarisa-
tion marked on the latch (potential „+").
CAUTION: Wrong battery mounting may cause device damage.
6. Put the removed printed-circuit board back in the base.
7. Put back the button.
8. Check correct operation – LED diode should switch on in the same way as during trans-
mission.
1
CAUTION: SUBSTITUTING THE BATTERY WITH ANY BATTERY OF INCORRECT
TYPE MAY CAUSE AN EXPLOSIVE HAZARD. DISPOSE OF USED BATTERIES AS
2
STATED IN THE MANUAL.
Battery discharge status in application EXTA
LIFE.