Descargar Imprimir esta página

HT SOLAR-02 Manual De Instrucciones página 24

Ocultar thumbs Ver también para SOLAR-02:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
SOLAR-02
24
5.2.1
SETTING THE VALUES OF SENSOR 1 (PYRA OR MONO)
1. Press and hold the SET key while turning on the instrument by means of the
/ESC key. The unit shows the screen beside.
2. Use the arrow keys ▲and ▼to set the correct K sensitivity value reported on
the (front or rear) label, located on the sensor itself.
3. Press the SET key to confirm the value.
4. With sensor type Irr-P, press the ESC key to exit the programming mode,
saving the changes made. In case a sensor type Irr-S2 is used, it is necessary
to set the parameter "Alpha" instead.
5. Use the arrow keys ▲ and ▼to set the value of Te (Alpha) corresponding to
the value of sensitivity K previously set.
6. Press the SET key to confirm the value and go on setting sensor 2.
5.2.2
SETTING THE VALUES OF SENSOR 2 (MULTI)
1. Use the arrow keys ▲and ▼to set the correct K sensitivity value reported
on the (front or rear) label, located on the sensor itself.
2. Press the SET key to confirm the value.
3. Use the arrow keys ▲and ▼to set the value of Te (Alpha) corresponding to
the value of sensitivity K previously set.
4. Press the SET key to confirm the value.
5.2.3
SETTING THE VALUES OF SENSOR 3
1. With sensor type Irr-S2, press the ESC key to exit the programming mode,
saving the changes made.
2. Use the arrow keys ▲and ▼ to set the correct K sensitivity value reported
on the (front or rear) label, located on the sensor itself.
3. Press the SET key to confirm the value.
4. Use the arrow keys ▲and ▼to set the value of Te (Alpha) corresponding
to the value of sensitivity K previously set.
5. Press the SET key to confirm the value.
Rel. 4.00 - 22/11/22

Publicidad

loading