Descargar Imprimir esta página

Fulmo PLUS+ Manual De Instrucciones página 41

Publicidad

Idiomas disponibles

Idiomas disponibles

POSITION AND LOCATION
• This stove is for outdoor use only. Make sure you have sufficient ven-
tilation.
• Keep a safe distance between the stove and combustible materials
Recommended: 100 cm (top) and 100 cm (side) minimum.
• The stove should be placed on a firm and level floor.
• Never use the stove in a place where fuels, gasoline or other flam-
mable liquid or gaseous products are stored.
• To protect the stove from strong winds, secure the base to the floor
with screws.
GAS CHARACTERISTICS
• Use butane or propane only. We strongly recommend the use of Propane, as it has a lower freezing
point, suitable for outdoor appliances.
• The regulator and the rubber hose with clamps must comply with the regulations in force in each
country.
• The installation must be in accordance with local regulations. In the absence of this, it must be done
according to the standard for storage and use of Liquefied Petroleum Gases.
• A cracked, rusted or damaged cylinder can be dangerous and should be checked by the manufacturer
or supplier. Never use a cylinder with a bad valve.
LEAK TEST
The gas connections of the stove have been pre-tested by the manufacturer prior to shipment. A safety
check should be performed during installation at the place of use to avoid loosening of parts due to
shipping.
Make a soapy solution of one part water and one part soap. The soap solution can be applied with a
sprayer, brush or rag. Soap bubbles will appear in case of leakage.
The stove should be checked with a full cylinder. Make sure the knob is in the off position. Open the
gas passage of the regulator.
In case of leakage, close the gas passage of the regulator. Tighten the connections with the correspon-
ding clamps. Reopen the gas passage to check again. Repeat until the leak disappears.
No smoking during the leak test.
TECHO
100CM
41

Publicidad

loading

Productos relacionados para Fulmo PLUS+