A. CONSTRUCTION AND FEATURES
•
Transportable terrace/garden stove with tank housing.
•
Powder coated steel or stainless steel housing.
•
Heat emission by the reflector.
B. SPECIFICATIONS
• Use only propane, butane or their mixtures.
• Maximum power: 13000 watts
• Minimum power: 5000 watts
• CONSUMPTION:
APPARATUS CATEGORY:
TYPES OF GAS
GAS PRESSURE
REGULATOR OUTLET
PRESSURE
• Use the appropriate regulator according to the regulator outlet pressure as shown in the table
above.
C. INJECTOR TABLE
DEVICE CATEGORY
TYPES OF GAS
GAS PRESSURE:
ENTRANCE
OF HEAT
(Hs):(Qn)
INJECTOR SIZE
The marking, e.g. 1.90 on the injector, indicates that the injector size is 1.90mm
•
The hose and regulator assembly must conform to local code standards.
•
The regulator outlet pressure must comply with the gas category corresponding to the injector table.
•
The device requires an approved hose of 0.6 m length.
I3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
30mbar
37 mbar
I3+(28-30/37)
Butane, propane
Butane
Propane
OR their derivatives
28-30mbar 37 mbar
30 mbar
13kW (945g/h)
1.90 mm for the main burner
0.18 mm for pilot burner
I3B/P(30)
Butane, propane
Butane, propane
OR their derivatives
OR their derivatives
30 mbar
50mbar
30 mbar
50mbar
I3B/P(30)
I3B/P(50)
Butane, propane
OR their derivatives
50mbar
1.70 mm for the main
burner 0.18 mm for
the pilot burner
I3B/P(50)
I3B/P(37)
Butane, propane
OR their derivatives
37mbar
37mbar
I3B/P(37)
Butane, propane
OR their derivatives
37 mbar
1.80 mm for the main
burner 0.18 mm for
pilot burner
45