Descargar Imprimir esta página

Truper PISCA-AM Manual página 3

Publicidad

Technical data
Code
Description
Voltage
Frequency
Current
Power
Air flow
Temperature
Work cycle
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power requirements
WARNING
Tools with double insulation and reinforced insulation are built with a
polarized plug (one prong is wider than the other) This plug fits in any polarized outlet
and can only be connected one way. If the plug does not fit completely into the outlet,
reverse the plug. If it is not fitting, call a qualified electrician or install a polarized outlet.
Do not alter the plug in any way. Double insulation eliminates the need of a three-prong
grounded power plug or a grounded electric system.
When using an extension cable, make it has sufficient gauge to
WARNING
carry the current your tool will draw. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
the motor will overheat. The following table shows the right size to use depending on cable's length and the ampere
capability shown in the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
From 0 and up to 10 A
From 10 and up to 13 A
From 13 and up to 15 A
From 15 and up to 20 A
WARNING
When using power tools outdoors use
Use". These extension cables are specially manufactured for outdoors use and reduce the risk of electric shock.
30 minutes of work and 15 minutes of rest. Daily maximum 3 hours.
18 AWG x 2C with insulation temperature of 221 °F
The construction class of the tool is: Reinforced insulat
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
PISCA-AM
102578
Mimi heat gun
127 V
60 Hz
2.9 A
350 W
280 LPM
752 °F
Class II
The power supply cable has cable clamps type: Y
Extension Gauge
From 6 ft to 49 ft
18 AWG
16 AWG
14 AWG
8 AWG
grounded extension cable labeled "Outdoors
Authorized Service Center.
|
Higher than 49 ft
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH