3. Using your CO Detector
Start Up
After connecting the battery, all three LEDs light up briefly and the CO detector confirms
start-up with a beep.
After power on, the green LED flashes once per second within 60 seconds indicating
the preheated state. 60 seconds later the green LED flashed every 40 seconds indicating
that the unit is functioning properly.
Registering the CO Detector to the System's Receiver
For the CO Detector to identify itself to the system's receiver, perform the registration
either by entering the CO Detector's 11-digit serial code number or by the following RF
allocation steps.
Note: In case of performing device registering (enrollment) by entering the detector's 11-digit
serial number, make sure to use the serial number of the Main Unit (by scanning the QR sticker
on the package via the HandyApp application).
1. Set the system to Learn Mode.
2. Remove the batteries from the battery compartment and then reinsert the batteries,
paying attention to the polarity.
3. Wait until the system receiver indicates that it has received the allocation message.
LED Indication
LED
State
Green
Flash every 40 sec. Normal condition
Yellow
Steady
Red
Steady
Fault Warning Silence
When the alarm sounds in the fault warning state, pressing the TEST/SILENCE button
will cause the detector to enter silence status for about 9 hours. The FAULT indicator
(yellow LED) will flash repeatedly.
Description
Trouble
CO detector status
7