• Once the assembly is installed, keep the new manual
inlet valve closed and open the inlet valve connected to
the wall adapter (7). The measuring cup must be empty.
• Pour 0.25 liters of Ozonated Water or Hydrogen Pe-
roxide into the dosing glass interspersed at the entran-
ce of the equipment (8). Thread the glass correctly to
its head.
• The manual inlet valve and the tap must be closed.
Connect the equipment to the electrical power supply.
• Open the water inlet faucet to the equipment and the
tap, allowing it to start its function and letting it suck
the Ozonated Water or Hydrogen Peroxide into it. Fill a
1L jug with tap water. Before turning on the faucet, turn
the inlet key back on to lower the pressure. Refill the
dispenser with 0.25l of Ozonated Water and empty 1 li-
ter more water. Close the faucet. At this time the entire
circuit contains sanitizing liquid.
• After 10 mins. open the dispenser faucet (9) and let
mains water circulate for 5 mins.
• Empty the measuring cup. Before opening it, have a
container in your hand where you can empty it, as it
may be full of water.
6
CLOSED
OPEN
10
Glass
Prefiltration
CF
Entrance
7
OPEN
OPEN
CLOSED
Membrane
RO
8
Probe
quality
Postfiltration
CB
9
OPEN
43