USER MANUAL
For clamp types:
EN
04
© The Crosby Group LLC. Nothing from this original user instructions publication may, in any way
whatever, be replicated or published without prior written permission from The Crosby Group LLC.
1.
General
You have chosen a CrosbyIP lifting clamp.
CrosbyIP lifting clamps are the most reliable lifting clamps available. But using reliable tools does
not automatically mean that practices are reliable. The people who work with clamps play an
equally important role in reliable lifting. Ensure that everyone who works with CrosbyIP lifting
clamps has been instructed in the proper application of the clamps.
CrosbyIP provides a 10 year warranty for its clamps. To keep CrosbyIP lifting clamps in optimum
condition and keep warranty, regular maintenance is important. Preventive maintenance and repair
shall be carried by a repairer authorized by CrosbyIP. In order to benefit from this warranty pro-
gramme and for more details on maintenance procedures, please consult www.thecrosbygroup.
Check when
com/resources/crosbyip-10-year-guarantee for more information.
placing the
clamp that slings
Please read and understand these instructions before using the lifting clamp.
are not twisted.
It is not
2.
Safety precautions
permitted to stay
in the danger
Proper instruction for the personnel is of vital importance. This will contribute to maximum
zone of the load.
reliability in the working environment.
IPBC clamps may be applied per piece, per set, per three clamps or with several pairs
No changes may
simultaneously for the lifting of steel plates, beams and structures.
be made to
Ensure that each clamp receives its proportionate share of the load. When using two clamps
CrosbyIP
or more, a spreader beam is recommended.
clamps. Never
Hardness: With the standard clamps it is possible to lift steel with a surface hardness of 363
straighten,
HV10. For harder steel types contact your CrosbyIP Customer Service Centre.
attempt to bend
Contact your CrosbyIP Customer Service Centre before using this clamp for plates and
or heat treat
constructions that have a radius.
parts.
Temperature: the operating temperature is between –40 ºC (–40 ºF) and 100 ºC (212 ºF). For
other temperatures contact your CrosbyIP Customer Service Centre.
Clamps suited
There are restrictions for operation in special atmospheres (e.g. high humidity, explosive, saline,
for stainless
acid, alkaline).
steel, must be
Loads: For proper application of the clamp consult the load diagrams 1.
used only for
Ensure that all attachments between lifting eye and crane are properly fitted, secured and
handling
coupled.
stainless steel,
Use chains/cables which are longer than the width of the plate to be lifted. IPBC clamps may
to avoid contact
not be used when reeved.
corrosion.
Several plates may be transported or lifted per lift, only if the plates will not sag.
IPBC lifting clamps may be used for sagging, bended or joggled plates, however in that case
no more than one at the time.
Copyright © 2021 The Crosby Group LLC. All Rights Reserved.
IPBC
Horizontal lifting with pretension