22. Mount the cable sock (pos. 18 in fig. Top fixation
bracket with lifting and safety wires and cable
sock) to the top fixation bracket by the shackle,
and pull the motor cable through it, to the desired
position. See fig. Top fixation bracket with lifting
and safety wires and cable sock. The power
supply cable should be slightly tightened.
B
31
18
Top fixation bracket with lifting and safety wires and
cable sock
Pos. Description
B
Bolts
18
Cable sock
20
Fixation bracket
31
Hole for fastening a safety wire
Remove the lifting wire from the crane
before starting the flowmaker.
23. Remove the lifting wire from the winch clamp on
the top fixation bracket (pos. 20 in fig. Top fixation
bracket with lifting and safety wires and cable
sock). Coil up any additional lifting wire and fasten
it by a strap.
24. Use the lifting wire as a relief for the power supply
cable. For this reason, the lifting wire must always
be tightened. See fig. Mounting of the lifting wire
on the motor bracket.
25. Check the distance between the propeller and the
wall and the propeller and the bottom of the tank
when the motor bracket is resting on the depth
blocker. The flowmaker must never touch other
installations, bottom or wall.
20
WARNING
Electric shock
Death or serious personal injury
‐
Before making electrical connec-
tion, make sure that the fuses have
been removed or the main switch
has been switched off.
‐
Make sure that the power supply to
the control cabinet is switched off.
26. Connect the power supply cable to the terminals
in the control cabinet.
23