Fireplace Installation (continued)
Electrical
120V Installation - Direct
Wire
CAUTION: Use the appropriate
wire to meet local and national
electrical codes for rated power
consumption.
To 120V direct wire:
1. Cut the wire to an appropriate
length.
2. Connect the L wire from the
unit to the live wire from the
power supply with a wire nut.
3. Connect the N wire from the
unit to the neutral wire from the
power supply with a wire nut.
4. Connect the G wire from the
unit to the ground wire from the
power supply with a wire nut
or attach the grounding wire
Figure 6
WHITE - N
BLACK – L1
GROUND - G
10
All manuals and user guides at all-guides.com
5. Ensure that all wires are secure
6. Continue to the final assembly
120V Installation - Wall
Switch
WALL
SWITCH
to the cover with the provided
grounding screw, by placing the
wire in-between screw and lock
washer and tighten (Figure 3).
and do not protrude past the
flame panel, so as not to be
visible after final assembly.
instructions.
!
NOTE: Use a single pole, single
throw (On/Off) wall switch that is
rated for a minimum of
15 amps.
CAUTION: Use the
appropriate wire to meet local
and national electrical codes
for rated power consumption.
WHITE – N
BLACK – L1
GROUND - G
120 V
POWER
SUPPLY
(BREAKER
PANEL)