Descargar Imprimir esta página

IP Cleaning IPC CLEANTIME 40 Manual De Instrucciones página 31

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The batteries do not ensure the
normal work time (models with
battery only)
The storage battery gets flat
too fast during use, although it
has
been
charged
correct way and when tested
with a densimeter at the end of
recharging, it turned out to be
uniformly
charged
with battery only)
The storage battery gets flat
too
fast
during
use,
recharging with an electronic
battery-charger is too fast and
at the end the storage battery
gives the right voltage (about
2,14V for each empty element),
but it turns out to be not
uniformly charged when tested
with densimeter (models with
battery only)
• the poles and charging clips of
the
batteries
oxydized
• the electrolyte level is low
• the battery-charger does not
work or is unsuitable
there
differences in density between
the various elements of the
battery
• the machine is working with a
too high pressure on the brush
• the storage battery is new and
does not give 100% of its
expected capacity
in
the
(models
• the machine is used at its
maximum
continuous
autonomy is not sufficient
• the electrolyte has evaporated
and does not cover the plates
completely
• the storage battery, already
filled
with
the
Manufacturer, has been stored
for a too long time before being
recharged and used for the first
time
are
dirty
and
are
considerable
capacity
for
periods
and
the
acid
by
the
• clean and grease the poles
and
clips,
recharge
batteries
• add distilled water topping up
all elements according to the
instructions
• see instructions relative to
the battery-charger
• replace the damaged battery
• reduce pressure on the
brush
• it is necessary to "run-in" the
storage
battery
by
charges and discharges to
obtain
maximum
performance
• use, if possible, storage
batteries with larger capacity
or
replace
the
storage
batteries with others already
charged
• add distilled water, topping
up all elements until the
plates
are
covered
recharge the storage battery
• if the recharging with a
normal storage-charger is not
effective, it is necessary to
carry out a double recharging
consisting in:
- a slow recharging of about
10 hours with a current equal
to 1/10 of the rated capacity
expressed in 5 hours (ex.: for
a storage battery of 100Ah(5),
the current should be 10A,
realized by a manual battery-
charger);
- one-hour pause;
- charging with a normal
battery-charger
ENGLISH
the
20-30
and
23

Publicidad

loading

Productos relacionados para IP Cleaning IPC CLEANTIME 40