Descargar Imprimir esta página

BOMANN CL 6045 QC CB Manual De Instrucciones página 93

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Unrolling the Cooling Pipes
• Only remove the covering caps immediately before you connect the
cooling pipes in order to prevent soiling.
• If the pipes are bent or pulled too frequently, they will become rigid.
Do not bend the pipes more than three times.
• Carefully unroll the pipes as shown in diagram A. Avoid buckling.
It is extremely important that the condensed water pipe for the interior
unit be installed in correct fashion.
1. Lay the drain hose below the pipe and make sure there are no dips or
recesses.
2. The drain hose must be inclined downwards in order to facilitate the
flow of the condensed water.
3. Do not bend or twist the drain hose. Do not allow it to protrude. Do
not immerse the end in water. If the pipe is connected to an exten-
sion, ensure the connection when inserting it into the interior unit.
4. If the cooling pipes are laid as shown at No. 3 in the chapter entitled
"Alignment of the Cooling Pipes", then the pipes, the connecting cable
for the exterior unit and the drain pipe for condensed water must be
secured to the rear side of the appliance using pipe couplings.
5. Insert the pipe connector in the corresponding appliance.
6. Press the connecting pipe down firmly into the air conditioning unit
and make sure the connection is tight.
CAUTION:
Avoid buckling during positioning and only permit these tasks to be
performed by a certified specialist companies!
CL6045QCCB_IM
Connecting the Condensed Water Pipe for the Interior Unit
CAUTION:
Do not pull the pipe apart as shown in diagram B. Instead, unroll it
carefully.
Connections to the Interior Unit
CAUTION:
The air conditioning unit must be installed and / or connected by a cer-
tified refrigeration and air conditioning company. Improper installation
shall result in expiry of the warranty.
1. Remove the protective caps.
2. Check the connections for soiling or damage.
3. Connect the union nut with the connection thread on the interior unit.
In doing so, pay attention to the colour of the protective caps.
4. Tighten the connection using a suitable wrench.
NOTE:
Always observe the correct torque and observe the chart provided
entitled "Installation Information".
93
17.12.20

Publicidad

loading

Este manual también es adecuado para:

Cl 6046 qc cbCl 6047 qc cb