'SELF CLEANING FILTER' MANUAL
Warning light (C) on:
manually start the "Self-cleaning filter" function; press the orange switch (E).
Continuous operation of the "Self-cleaning filter" system for more than 60 seconds
may cause the thermal protection switch to trip.
AUTOMATIC SMARTCLEAN FUNCTION
Automatic Filter Shaking Function at 110 and 220V
With the vacuum cleaner, on and in use, after 55"~ the automatic filter shaking
function starts for 8 seconds, of which 6 seconds with motor ON and 2 seconds
with motor OFF at the end of the cleaning cycle the SMARTclean function repeats
endlessly.
While you are working if you vacuum an extreme dust quantity, the SMARTclean
function can be used in the MANUAL MODE pushing the orange button placed on
the main console for a time of 15 - 20 sec max.
If the air speed drops to below 20 m/sec., the warning light comes
20
DV 35|50 HBAN
on (in accordance with IEC/EN 60335-2-69)
MAX-VAC.COM