The appliance should be decontaminated by vacuum cleaning methods and
wiped clean or treated with sealant before being taken out of a hazardous area.
All the other appliance parts shall be regarded as contaminated when removed
from hazardous area and appropriate action taken to prevent dust dispersal.
During cleaning and maintenance, it is recommended to always wear personal
protection devices (gloves and mask) as required by the national regulations in
force.
Before proceeding with maintenance operations, it is strongly recommended to
first decontaminate the appliance by vacuuming clean air for a few minutes and
to clean it on the outside.
Maintenance and cleaning must be carried out in a room with adequate
ventilation and in such a way as not to endanger the operators or other persons.
Clean the place where maintenance is carried out in order to prevent that
hazardous substances are dispersed into the environment.
During maintenance, repair and disposal operations, all the contaminated parts
of the appliance that cannot be completely cleaned must be eliminated; put
them in impermeable bags according to the national regulations in force for
disposal of special waste.
For proper disposal, it is advisable to indicate on the impermeable bag which
substances have been vacuumed.
It is recommended to carry out a technical inspection on the appliance at least
once a year to check that the seals are tight and proper functioning of the
control mechanisms so that any malfunctions can be detected. Daily check the
integrity of the filter system.
8
DV 35|50 HBAN
MAX-VAC.COM