Descargar Imprimir esta página

Sime ECOMAXI VB 80 Instrucciones De Instalación Y Funcionamiento página 78

Publicidad

Idiomas disponibles

Idiomas disponibles

■ Technical Parameters
Model
Operational mode
Power supply
Max. power input (under boost mode)
Max. current input (under boost mode)
Max. power input
Heating up time(7/6℃)
Heating up time(14/13℃)
Refrigerant
Declared load profile
COP
DHW
Heat pump
COP
DHW
Mixed water at 40℃
Energy efficiency(7/6℃)
Energy efficiency(14/13℃)
Energy efficiency class
Max. outlet water temp.
Operating temp. range
Rated power input
Electric
heating
Max. outlet water temp.
Max. operating pressure for refrigerant
circuit (discharge side/suction side)
Rated capacity
Storage
Max. operating Pressure
tank
Water inlet/outlet
Anti-electric shock class
Sound power level
Net weight(kg)
Gross weight(kg)
Dimensions(mm)
Note (1): The test conditions for rated parameters are dry-bulb temperature of 7℃/14℃, wet-bulb
temperature of 6℃/13℃, inlet water temperature of 10℃, outlet water temperature of 50℃, according
to EN 16147:2017, (EU) NO 814-2013.
Note (2): Sound power level tested with air duct, according to EN 12102-1-2017, ISO 3744:2010.
ATTENTION
The parameters in the above table are only for reference. When the contents of this table differ
from those of the nameplate on the appliance, please refer to the nameplate.
(7/6℃)
(14/13℃)
ECOMAXI VB 80
Heat pump, Automatic and Boost mode
220-240V~ 50Hz
2300W
10.2A
800W
2:25 (h:min)
1:56 (h:min)
R134a/540g
M
2.45
2.77
79L
104.7%
117.6%
A
+
65℃ (default 50℃)
-7℃~43℃
1500W
75℃
2.4MPa/0.6MPa
80L
0.8MPa
DN15
Class Ι
58dB (A)
57
71
560*575*1230
14
ECOMAXI VB 120
2300W
10.2A
800W
4:05 (h:min)
3:25 (h:min)
R134a/540g
M
2.45
2.89
135L
102.1%
121.0%
A+
120L
60dB (A)
67
85
560*575*1550

Publicidad

loading

Este manual también es adecuado para:

Ecomaxi vb 12081158408115842