1.
Attach the rangetop in the cabinet opening by
driving four screws into the countertop. Install
2 screws per side using preferred hole options
based on countertop construction. If countertop
is wooden, start by drilling pilot holes with a
the holes to attach.
NOTE: There should be an unobstructed vertical
gap of .25" under the rangetop to allow for proper
gap.
2. GAS SUPPLY
WARNING
Fire Hazard: Do not use a
WARNING
Explosion Hazard: Do not
the pressure regulator resulting in fire or
explosion hazard.
WARNING
detected by smell alone. Gas suppliers
recommend your purchase and install an
UL approved gas detector. Install and use
in accordance with the manufacturer's
instructions.
Gas Pressure Regulator
regulator supplied with this rangetop. For proper
operations the inlet pressure to the regulator
should be as follows:
49-2001154 Rev. 0
Installation Instructions
2.
Female connection to the regulator in the upper
left rear corner of the cabinet
Tighten the gas line to the regulator using 2
wrenches.
IMPORTANT: Leave adequate space around
the gas supply pipe in case of bend or damage
during installation. Make sure the gas supply
pipe cannot contact any moving parts after
installed.
When using pressures greater than ½ psi
valve from the gas supply piping. When using
test the gas supply system, simply isolate the
rangetop from the gas supply system by closing
Line Connection