3. PRESSURE CHECK
Ensure propane gas is turned off to the
appliance.
Remove the screw with the sealing gasket from
the pressure test port on the rangetop.
Screw
Sealing
Gasket
measuring device, slide the rubber tube down
over the gas pressure test port. The rubber
tube should seal around the pressure test port.
Turn on the propane gas to the appliance.
The pressure gauge tester should measure
Turn off the propane gas to the appliance.
Remove the rubber tube of the pressure check
measuring device.
Replace the screw with the gasket removed
inspect the rubber gasket seal for any signs of
damage.
Hand tighten the screw ensuring not to
damage the seal.
NOTE: Ensure the product is gas leak checked
after the pressure check test is completed by
also testing the pressure check port screw. If
any leaks are detected around the pressure test
port screw and sealing gasket, a new one can be
for a replacement.
Installation Instructions
4. LEAK CHECK
Make sure all control knobs are in the OFF
position.
Apply a gas leak detection liquid to the
connections. Any gas leaks will be indicated by
bubbles.
If a gas leak is detected, tighten the loose joint,
or replace the faulty part with a replacement
part recommended by a GE Appliances
authorized retailer.
5. ELECTRICAL CONNECTION
CAUTION
PRODUCT DAMAGE HAZARD
• Connect to 12V DC service only.
• Connect only to protected circuit fused for
not more than 15 Amps.
The power supply wires are located at the top left
corner of the rear of the appliance.
Connection
NOTE: Ensure to connect the wires with the
Ensure electrical connections are properly
secured.
Ensure electrical supply lines are disconnected,
or power removed at the main fuse or circuit
breaker panel, before servicing the appliance.
49-2001154 Rev. 0