Descargar Imprimir esta página

Interlogix RF711I4 Hoja De Instalación página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 4
freeze sensor will trigger when the temperature is below 5°C
(41°F) and will send a restoral at 7°C (45°F).
Placement
Place the sensor anywhere that you wish to detect water
and/or freezing temperatures, such as under a sink, near a hot
water heater, in a basement or behind a washing machine.
Determine this location is suitable for the sensor by following
the procedure in the section "Testing the Sensor" ensuring
desired signal strength is achieved. If you would like to make
sure the sensor does not move from its intended location, use
the optional sensor bracket available from your supplier (see
Figure 4) and secure it either to the floor or the wall.
Where possible, install sensors within 30 m (100 ft.) of the
panel. While a transmitter may have an open-air range of
120 m (400 ft.) or more, the environment at the installation site
may have a significant effect on operational range. Changing a
sensor location may improve wireless communication.
Testing the Sensor (Test Weekly)
The sensor test verifies proper communication between the
sensor and the panel/receiver. To test the sensor, refer to the
specific panel/receiver documentation and do the following:
1.
Put the panel/receiver into sensor test mode.
2.
By using a magnet you can send a Flood OR Freeze
transmission:
Swiping a magnet 1 time (in/out) next to the line
located on the side of the case causes sending flood
trigger and restore signals.
Swiping a magnet 2 times causes sending freeze
trigger and restore signals.
Placing wet fingers on any two probes will also trigger
a flood transmission.
3.
Listen for siren beeps to determine the appropriate
response.
4.
Exit sensor test mode.
Replacing the Battery
When the battery is low, a signal will be sent to the control
panel. To replace the battery:
1.
Carefully remove the white rubber feet on the bottom of
the flood detector.
2.
Remove the 3 screws and open the case. Replace the
battery with a CR2450 lithium battery.
3.
Replace the screws and rubber feet.
Specifications
Compatibility
Interlogix Learn Mode Panels and Receivers
Models
RF711I4
Wireless operating
433 MHz
frequency
Maximum power
-3.6 dBm
output
Battery
3 V lithium CR2450
Battery Life
Up to 10 years
Supervisory Signal
64 min (approximately)
Interval
2 / 14
at 5°C (41°F) restores at 7°C (45°F)
Detects Freeze
Detects Water
Minimum of 0.397 mm (1/64 inch) of water
Dimensions (WxH)
6.35 x 0.9398 cm
Weight
23 g
Colour
White
Operating environment
Temperature
0 to 49°C (32 to120°F)
Relative humidity
5 to 100% noncondensing
Regulatory information
Manufacturer
Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR SALE
and disclaimers
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
European Union
UTC Fire & Security hereby declares that this
directives
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
https://www.utcfssecurityproducts.eu/
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info
This product may contain a battery that cannot be
disposed of as unsorted municipal waste in the
European Union. See the product documentation
for specific battery information. The battery is
marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling return the
battery to your supplier or to a designated
collection point. For more information see
www.recyclethis.info
Contact information
www.utcfireandsecurity.com or www.interlogix.com
Customer support
For customer support, see www.utcfssecurityproducts.eu
or scan the QR code.
P/N 466-5253 • REV F • ISS 21MAR19

Publicidad

loading