Descargar Imprimir esta página

Sagola HT 10 Manual De Instrucciones página 42

Ocultar thumbs Ver también para HT 10:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
In the case of any breakdown during the guarantee period, deliver this to the nearest Technical
Assistance Service or get in touch with the factory.
Any demand of greater importance against the supplier, in particular compensation for damages,
is excluded. This is also applicable to any damages that might arise during counselling, while
acquiring practice and during demonstration.
Consequently, the services rendered under guarantee do not involve an extension of the warranty
period.
The manufacturer reserves the right to make technical modifications.
17. Disposal
For complete and correct disposal of the equipment, when it has reached the end
of its useful life, it must be completely dismantled so it can be recycled, separa-
ting the metal and plastic components.
18. Troubleshooting
MALFUNCTION
The unit does
not start
The Unit
does not suck in
any product
NOTE: The symbol (*) means that before starting the procedure it is necessary to release pressure (see
paragraph 10.1)
CAUSE
Compressed air supply
malfunctioning
Malfunction in the pneumatic system Consult S.A.T. SAGOLA
Pressurised unit
The product container is empty
The suction Filter is obstructed
The suction Probe is loose, blocked
or damaged
The pressure Regulator is set at
minimum
The purge Valve is closed
The suction Probe is stuck, dirty or
damaged
Gaskets in poor condition
The hydraulic mechanism is loose or
faulty
ENGLISH
REPAIR
Make sure the supply hose
is not obstructed.
Make sure the unit is
properly connected to the
mains supply.
Make sure the compressed
air valve is Open (*)
Depressurise the unit (*)
Refill it
Replace or clean. (*)
Check the connection of the
probe to the unit or replace it
Increase the pressure by
adjusting the
regulator.
Open it (*)
Replace or clean. (*)
Replace (*)
Tighten it or replace

Publicidad

loading

Productos relacionados para Sagola HT 10

Este manual también es adecuado para:

Ht 15Ht 25