Descargar Imprimir esta página

Assa Abloy CMD Manual Del Usuario página 14

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 76
Safety accessories
Even though the ASSA ABLOY CMD is installed to comply with all applicable safety regulations, it is
possible to enhance safety/comfort with the following add-ons (please contact your local
ASSA ABLOY Entrance Systems company for detailed description).
Combined motion and presence sensors
Separate presence sensors (presence in the door opening or side presence for the trailing edge
of the door)
General accessories
Your ASSA ABLOY CMD can be further improved with the following add-ons (please contact your
local ASSA ABLOY Entrance Systems dealer for detailed description).
Cover
Made in clear anodized aluminium as standard. Paint finished in RAL colours or anodizing optional.
Motion sensor and presence sensors
Add motion and presence sensors to improve comfort and safety.
Programme selectors
See page 7.
Electrical locks
The following locks are available to the operator:
Locked with power (LDP), fail safe
Locked without power (LD), fail secure
Bistable lock (LDB)
Micro switch kit, LSK/LIS
For indication of door and lock position.
Electrical emergency unit with batteries
Used if a door is required to be opened or closed by means of a rechargeable battery unit and remain
in this position in the event of power failure. Authorities can demand that the emergency units are
monitored on a regular time basis. Half an hour before this time has elapsed the following opening
impulse generates an emergency opening test. If there is no opening impulse within the next half
hour, the operator control unit generates the opening impulse itself.
If the battery opens the door within the limited time the test is successful and the door resumes the
function set by the programme selector.
Note! The test is never performed in programme selector setting OPEN. In setting OFF it can be se-
lected. The test is always performed after a RESET and after changing program selection, from a pos-
ition where a test is not done to a position where the test is a demand.
Emergency closing with repeated closing
If the door is opened by hand after an electrical emergency closing, it will close again.
Mechanical emergency unit with elastic cord
Used if a door is required to be opened and remain opened by means of an elastic cord in the event
of power failure. Authorities can demand that the emergency unit is monitored on a regular time
basis. Half an hour before this time has elapsed the following opening impulse generates an emergency
opening test. If there is no opening impulse within half an hour, the operator control unit generates
the opening impulse itself.
14
Issue 2018-03-09
1006492-en-3.0

Publicidad

loading