PS-5M, for central control of an optional number of operators. In setting AUTO every connected
operator are individually controlled by its own programme selector. Reset is not available on
PS-5M.
PSK-6U, surface mounted on the side screen or on the wall close to the door.
Programme selector functions
OFF
EXIT
AUTO
AUTO
PARTIAL
OPEN
RESET
PSO-5R
PSO-5T
PSMB-5
RESET
R
PSK-6U
Note! If monitored emergency unit is a demand, a test of the emergency unit is performed when
the programme selector is turned from OFF or OPEN to any other position.
Locking
Doors used for emergency escape in buildings such as hospitals and homes for elderly people may
not be locked or put in programme selection OFF mode. In other buildings emergency escape doors
may be locked or put in programme selection OFF mode after it has been secured and all people
have left the building.
Unlocking
Unlock all the mechanical locks before activating the operator.
8
This function is only used on emergency escape doors after it is certain
that all people have left the building.
The door cannot be opened with inner and outer activation units. The
door is locked if an electromechanical locking device has been fitted. The
door can be opened partially with a key switch (if fitted). With an emer-
gency push-button (if fitted) the door opens fully.
Passage from inside only. The door is normally locked if an electromech-
anical locking device has been fitted. The door can only be opened with
the inner activation unit or with a key switch/emergency push-button (if
fitted).
Two-way traffic, normal operation of the door. The door can be opened
with the inner and outer activation units and with a key switch/emergency
push-button (if fitted).
Two-way traffic, AUTO PARTIAL is obtained. The door can be opened
partially with the inner and outer activation units and with a key switch
(if fitted). With an emergency push-button the door opens fully.
The door is permanently open. The door can be moved by hand e.g. for
window cleaning. All activation units except for the emergency push
button (if fitted) are disconnected.
Set the programme selector to AUTO. Insert a narrow object in the small
hole on the programme selector and push briefly. The operator makes a
system test of the emergency unit (if selected), electromechanical lock,
watchdog relay and closed door position. The operator is after closing
reset and ready for normal operation.
Note! The RESET is not available on programme selector PS-5M.
Turn the key clockwise to the position "R" (six o'clock) and insert a narrow
object in the small hole on the programme selector and push briefly. Then
turn the key counter-clockwise back to the requested setting. The oper-
ator makes a system test of the emergency unit (if selected), electromech-
anical lock, watchdog relay and closed door position. The operator is after
closing reset and ready for normal operation.
Note! The key cannot be removed in the "R" position.
Issue 2018-03-09
1006492-en-3.0