SET UP & USE
Pump draining (Pump model CCD50PJW only)
The internal pump allows the unit to operate without having to empty the bucket.
To install the included Drain Hose Kit, remove the drain cap on the back of the unit.
Insert the included drain hose adapter and turn clockwise, Insert the Drain Hose onto
the Drain Adapter.
Once securely installed, lead the drain hose to a nearby drain, sink or out of a window
up to 16 ft height from the base of the unit. (Make sure there are no kinks or knots in
the hose).
Turn on the unit and press the pump button to activate the internal pump. When the
water tank is detected to be full of water, the pump automatically begins removing
water and will stop after 90 seconds. The cycle will continue until the pump button is
pressed again and deactivated. If the drain kit is not installed and the pump button is
not activated, the pump will not work.
CAUTION: PUMP MODE WILL ONLY OPERATE WITH THE INCLUDED DRAIN HOSE
AND DRAIN ADAPTER
NOTE: When the continuous draining feature is not being used, remove the drain
hose from the outlet, and dry the water in the continuous drain hose outlet.
NOTE: The pump may make a loud noise when it starts to work for 3~5 minutes. This
is normal.
• Make sure the hose is secure so there are no leaks.
• Direct the hose toward the drain, making sure that there are no kinks that will stop
the water flowing.
• Select the desired humidity setting and fan speed on the unit for pump draining to
start.