Owner's Manual
1.10 Troubleshooting
FAULT
Unit does not
operate
Unit operating, but
room not dry
Unit continuously
in defrost mode
Pump does not
function
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or
contact the
Dri-Eaz Service Department toll-free at 800-932- 3030.
DrizAir 1200 Owner's Manual
CAUSE
Unit not switched
on.
No power to
machine.
Not enough time to
dry.
Poor air movement
in room.
Excessive moist air
infiltration.
Room temperature
too low
Stuck float valve
Room air is dry.
Room temperature
is too low.
SOLUTION
Switch unit on.
Plug in unit; check power cord
connection at wall outlet.
Allow more time for drying.
Increase air movement with air
movers.
Reduce infiltration.
Increase room temperature.
Clean float valve shaft.
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as
necessary.
19