Descargar Imprimir esta página

LG 17HK700G-W Manual Del Propietário página 3

Ocultar thumbs Ver también para 17HK700G-W:

Publicidad

OPEN SOURCE SOFTWARE NOTICE
INFORMATION
To obtain the source code under GPL, LGPL, MPL, and other open source licenses, that is contained in this
product, please visit http://opensource.lge.com.
In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are
available for download.
LG Electronics will also provide open source code to you on CD-ROM for a charge covering the cost of performing
such distribution (such as the cost of media, shipping, and handling) upon email request to
opensource@lge.com.
This offer is valid for a period of three years after our last shipment of this product. This offer is valid to anyone
in receipt of this information.
ON CLEANING
Recommended Cleaning Chemicals
Isopropanol 70 %
Ethanol 70 %
Cidex
®
OPA
0.9 % NaCl solution
How to Use Cleaner
Prior to cleaning, turn off the detector and remove the power cable.
Soak a soft cloth in a recommended cleaner, then lightly rub the screen with no more than 1 N of force.
The cleaner could cause serious damage if it leaks inside the detector while cleaning.
Do not use benzene, thinner, acids or alkaline cleaners or other such solvents.
Cleaning guidelines for detector must only be carried out by medical professionals (doctors or nurses) and
must not be handled by patients.
GENERAL DESCRIPTION
Overview
This model is an x-ray imaging device, a system that can acquire and process X-ray images as digital images. It
utilizes amorphous silicon and a high-performance scintillator to ensure sharp high-definition image quality
with the resolution of 3.6 lp/mm and the pixel pitches of 140 um. This device is a flat panel based X-ray image
acquisition device. This device must be used in conjunction with an operating PC and an X-ray Generator. This
device can be used for digitizing and transferring X-ray images for radiological diagnosis. The data transmission
between the detector and PC can be enabled with a wired (cable).
Product Components
Detector:
System Controller:
- AC Power Cord for the System Controller
Cable
- Main Cable: Detector and System Controller link cable (Supply DC power, Ethernet data, control signals of
X-ray Generator)
- Trigger Cable: X-ray Generator to System Controller, transmit control signal between detector and X-ray
Generator.
- LAN Cable: System Controller to PC, exchanges Ethernet data between PC and detector.
CD:
Owner's Manual (Detector, System Controller), Inspection Report