Blanking of Motion Zone
The motion zone can be blanked in 7 steps for all three directions using the 3
rotary switches "Left", "Center" or "Right" (see fig . 9) .
Fig . 9
MOTION AREA ADJUSTMMENT
MIN
MAX
MIN
MAX
LEFT
CENTER
Blanking left
TEACH-IN
the zones it must be verified that the motion zone is active in the wanted area
by a "walking test" .
Immunity
Max Immunity
1
2
Min
The sensitivity rotary switch allows settings in 7 steps . In order to select the
right compromize between sensitivity and immunity .
• A normal setting would be 3-5 (Normal light condition) (4 is default) .
• For indoor applications with light shadows, setting at 6-7 can be used .
• In outdoor conditions with strong light, rain or snow, a setting from 1-2
could be selected (strong light with heavy shadows) .
MIN
MAX
RIGHT
Adjust Sensitivity
MIN
MAX
SENSITIVITY
3
4
Recommended settings
Blanking center
Blanking right
After adjusting
ON
1 2 3 4 5 6
5 MIN
1 MIN
30 SEC
10 SEC
PRESENCE
TIME
5
6
Presence zone
Motion zone
DIP
Sensitivity
Max Sensitivity
7
Max
11