Fig . 10
1 MIN
30 SEC
10 SEC
MIN
MAX
SENSITIVITY
According to DIN18650-1, EN12978, the door control system must have a
test function, which checks the presence detector for correct function and
connection at least once per door cycle .
Active high, test pulse: 12-24 VAC/DC
Active low, test pulse: 12-24 VAC/DC
See test sequence (Operating Diagram) on page 66
Carlo Gavazzi Industri A/S, Over Hadstenvej 40, DK-8370 Hadsten, Denmark,
declare that the ESPE type 2 product Guardian 2 is in conformity with:
Low-Voltage Directive 2006/95/EC
EN60947-1: 2007 Low-voltage switchgear and control gear - General rules
EMC Directive 2004/108/EC
EN61326-1: 2006 Electrical equipment for measurement . Control and labora-
tory use – EMC requirements – Part 1: General Requirements
EN61000-3-1: 2008 Electrical equipment for measurement, control and
laboratory use - EMC requirements - Part 3-1: Immunity requirements for
safety-related systems and for equipment intended to perform safety-related
functions (functional safety) - General industrial applications
Machinery Directive 2006/42/EC
EN ISO 13849-1: 2008 Safety of machinery - Safety-related parts of control
systems - Part 1: General principles for design
DIN18650-1: 2005 Building hardware . Powered pedestrian doors .
Part 1: Product requirements and test methods
prEN16005: 2009 Powered pedestrian doors - Safety in use of power pedes-
trian doors - Requirements and test methods
EN 12978: 2003 + A1: 2009
Person authorised to compile the technical file:
K . Soerensen, Carlo Gavazzi Industri A/S, Over Hadstenvej 40,
DK-8370 Hadsten, Denmark
EC type examination No . 44 205 09 555114 .
Notified body 0044
TÜV NORD CERT GmbH, Langemarckstr . 20, 45141 Essen, Germany
Hadsten, 3 June 2010, K . Soerensen (R&D Manager)
The sensor surface must be cleaned with soft cotton . Light soap water can be
used . No alcohol must be used as the frontglass can be miscoloured .
12
ON
1 2 3 4 5 6
Presence Time Settings
5 MIN
PRESENCE
TIME
0 VAC/DC
0 VAC/DC
EC Declaration of Conformity
DIP
The presence time is used to "hold" the door
open if a person or object is present and not
moving in the presence zon . After the "Presence
time" has expired, the doors will close . If an
person or object has not moved within the
"Presence time", the person or object will be
stored as part of the background . The "Present
time" can be set on the rotary switch for 10 sec,
30 sec, 1 min or 5 min . See fig . 10
Test Input
Maintenaince
t
t