Code:
Meaning:
5
5
Bottom stop – Right hand
Top stop – Left hand
Description:
End limits activated.
Telephone fault finding action:
Ask client to tap trunnion guards in case they are stuck.
If this does not correct the fault – send engineer.
On site fault finding action:
Check end limit circuit and trunnion guards.
Code:
Meaning:
7
7
Low voltage
Description:
Batteries approaching critical level.
Telephone fault finding action:
Ask client to drive lift to charge contacts – if 'Okay'
code does not show send engineer. If the lift will not
drive – send engineer.
On site fault finding action:
Drive lift to charge contacts. Check charging circuit if
'Okay' code not displayed. If lift will not drive replace
batteries and check charging circuit.
Code:
Meaning:
9
Up direction – Left hand
Down direction – Right hand
Description:
Shows when toggle switch is activated in down/up
direction.
Telephone fault finding action:
None.
On site fault finding action:
None.
Code:
Meaning:
b
Switch active
Description:
A switch is active at power on i.e. Toggle Up,
Toggle down, IR Up IR down or learn.
Telephone fault finding action:
Send engineer.
On site fault finding action:
A short circuit has occurred on toggle circuit
– check circuit.
6
Description:
Safety edge (down/up direction) activated
– footplate, underpan.
Telephone fault finding action:
Ask client to tap footplate edges. If this does not
correct the fault – send engineer.
On site fault finding action:
Check footplate bottom and downside and chassis
underpan.
8
Description:
Shows when toggle switch is activated in up/down
direction.
Telephone fault finding action:
None.
On site fault finding action:
None.
A
Description:
Telephone fault finding action:
None.
On site fault finding action:
None.
C
Description:
The IR Address (Dip switch) does not match.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Re-program handsets.
HANDICARE 2000 SIMPLICITY / STYLE INSTALLATION MANUAL 47
Code:
Meaning:
6
Bottom pressure – Right hand
Top pressure – Left hand
Code:
Meaning:
8
Up direction – Right hand
Down direction – Left hand
Code:
Meaning:
A
Hinge open
Code:
Meaning:
C
IR Address fail