Descargar Imprimir esta página

Handicare 2000 SIMPLICITY Manual De Instalación página 54

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 242
Appendix 3
HAN125 Internal RTC reed switch connections
MS125 Internal RTC Reed Switch Connections
(INTERNAL CURVE CONNS)
WHEN LOOM 181001. 50062 IS
PLUGGED INTO THE 4 WAY
CONNECTOR, 2 ORANGE + 2 RED
WIRES WILL BE AVAILABLE TO
CONNECT INTO.
TRACK SECTION DOWNSTAIRS
POSITIVE
CHARGE CONTACT
NOTE: ON A 1000 LIFT, POWER SUPPLY CAN BE WIRED FROM BOTTOM TRACK SECTION IF REQUIRED.
SIMPLY FIT END CAP PRESSING (WITH EARTH CABLE) ON TRACK SECTION DOWNSTAIRS.
ON A 2000 LIFT, POWER SUPPLY CAN BE WIRED FROM TOP, BOTTOM OR MIDDLE OF TRACK
SECTION IF REQUIRED.
54 HANDICARE 2000 SIMPLICITY / STYLE INSTALLATION MANUAL
1234
Standard track wiring – LH and RH
RED
JUMPER POSITION
POSITION A
POSITION B
CONNECTION WITH ONE SWITCH:
CONNECT ORANGE (1) TO ONE SPADE CONNECTOR
CONNECT RED (4) TO SECOND SPADE CONNECTOR
SET JUMPER ON PCB TO POSITION A
SAME CONNECTION REGARDLESS OF LIFT HAND
CONNECTION WITH TWO SWITCHES:
LEFT HAND
ORG (1 & 2) = UPPER REED, RED (3 & 4)= LOWER REED
RIGHT HAND
ORG (1 & 2) = LOWER REED, RED (3 & 4)= UPPER REED
SET JUMPER ON PCB TO POSITION B
O/C ON CIRCUIT = HALF SPEED
S/C ON CIRCUIT = FULL SPEED
TRACK SECTION UPSTAIRS
RED
RED
POSITIVE
CHARGE CONTACT
33VDC (WHITE)
BLACK
0V (SHIELD)
FROM
POWER SUPPLY

Publicidad

loading

Este manual también es adecuado para:

2000 style