– The plug and the socket can be easily reached
and are positioned so that no live part is
accessible when inserting or removing the plug.
– A 3 x 0.75 mm
2
completely gas hobs is used when replacing the
power cable.
– The terminals of two appliances are not
connected to the same plug.
– The polarities of the free terminals
(Blue = Neutral = (1) /Yellow and Green = Earth
=(2) / Brown = Live = (3)) are respected.
1
2
3
Adjustment to different types of gas
WARNING: This operation must be performed by
a qualified technician.
Minimum flame adjustment
Remove the knob.
X
Adjust the minimum flame by turning the
X
screw clockwise to decrease the flame and
anticlockwise to increase it. The screwdriver for
adjustment is supplied with the accessories.
Replacing injectors
Not supplied injectors must be requested to the
customer service.
Important: All the appliances are factory-set for
natural gas (G20). If a different type of gas is to be
used, change the injectors as follows:
FHNE 604 3G TC / FHNE 755 4G TC / FHNE 805 4G TC / FHNE 805 4G TC FM /
FHNE 1204 3G TC / FHNE 1204 3G TC FM / FHNE COR4 3G TC
H05RR-F type cable for
L
N
-
+
– Remove the grids, burner caps and flame-
spreaders;
– Unscrew the injectors and replace them with
those provided and suitable for the gas supply,
making sure the marking matches that given in
the table;
– Refit the flame-spreaders, burner caps and grids.
These burners do not require air adjustment.
Accessing the hob
To access the tray containing the functional parts,
proceed as follows:
– Remove the grids, burner caps and
flame-spreaders;
– Remove the knobs, sliding them off their pins;
– Remove the screws that fix the burners to the hob;
– Lift the hob.
Important: When converting the appliance to
a different type of gas, place the corresponding
sticker (supplied as an accessory) in the special
space on the data plate. For operation with LPG
(G30 or G31), the minimum flame adjustment
screw must be fully screwed down. These
appliances are supplied in cat. II 2H3+.