2.DESCRIPTION
EN
FR
1. Speed control knob
Fan power input(P):
Maximum fan flow rate (F):
Service value (SV):
Standby power consumption (PSB):
Fan sound power level (LWA):
Maximum air velocity (c):
Measurement standards for service value:
3.INSTALLATION
ASSEMBLING THE BASE ( fig. A-E).
Ensure that the appliance is positioned in accordance with the safety instructions before turning it
on.
The appliance must be used solely as a portable, auxiliary device.
Before using this appliance, ensure that it is placed on a flat, stable surface.
Place the appliance at least 100 cm away from the wall, furniture and curtains.
4.OPERATION
0
0
5.MAINTENANCE & CLEANING
Always unplug the appliance before cleaning.
Clean the appliance with a soft, dust-proof cloth.
You can use a vacuum cleaner to remove dust and lint trapped in the ventilation grilles.
Never use harsh cleaning products. Prevent the appliance from coming into contact with acidic
substances.
Store away from dust and freezing temperatures.
Turn the timer as desired.
You can select up to 120 minutes of operation. When the selected time has
elapsed, the appliance will stop automatically. You can, however, turn off the
appliance manually at any time by turning the timer anticlockwise to the OFF
position.
0
Turn the speed and oscillation control knob to your desired setting:
0
• Speed 0 : no ventilation
• Speed
: low ventilation /
0
• Speed
: medium ventilation /
0
• Speed
: high ventilation /
0
0
2. 120-minute timer
32.9 W
24.82 m³/min
0.75 (m³/min)/W
0.00 W
58.1 dB(A)
2.33 meters/sec
EN IEC 60879:2019
0
0
0
oscillating function
oscillating function
oscillating function
0
0
0
6