CONTROL PADS ON THE DEHUMIDIFIER

NOTE: The control panel of the unit you purchased may be slightly di erent according to the
models.
Continuous
operation on
Auto defrost operation
Clean lter
indicator light
on indicator light
indicator light
Comfort dehumidifying
operation on
Auto defrost
indicator light
Pump operation
on indicator light
2
1
Fig.1

Control pads

When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.
PUMP Pad(on some models)
1 1
Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed
into the unit and the continuous drain hose is removed
fromthe unit before the pump operation is activated.
When the bucket is full, the pump starts to work.Refer
to the next pages for removing the collected water.
Do not use this operation when the outdoor temperature
is equel to or less than 0 C (32 F).
COMFORT Pad(optional)
2
2
Press to activate the comfort dehumidifying operation.
NOTE: In this operation, the unit's humidity level can not
be set.
3
3
FILTER Pad
The check lter feature is a reminder to clean the
Air Filter for more e cient operation. The Filter
light(Clean lter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the lter, press
the Filter pad and the light will go o .
CONTINUE Pad
4
4
Press to activate the c ontinuous dehumidifying operation.
Bucket full
Timer on/o
High fan
indicator light
indicator light
indicator light
Full
On
O
3
4
5
6
7
TURBO Pad
5
5
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
Timer Pad
6
6
Press to initiate the Auto start and Auto stop feature,
in conjuction with the
and
: Up/Down Pads
7
7
Humidity Set Control Pads
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.
Power Pad
8
8
Press to turn the dehumidi er on and o .
4
9
Display
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(
5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
9
Error Codes and Protection Code:
AS - Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES - Tube Temperature sensor of the evaporator error-- Unplug
the unit and plug it back in. If error repeats, call for service.
P2 - Bucket is full -- Empty the bucket.(only available for the
unit with pump feature.)

Other features

8
Bucket Full Light
Glows when the bucket is ready to be
emptied.
Auto Shut O
The dehumidi er shuts o when the bucket is
full, or when the bucket is removed or not replaced
in the proper position. When the set humidity level
is reached, the unit will be shut o automatically.
For some models,the fan motor will continue
operating.
Auto Defrost
When frost builds up on the evaporator coils, the
key pads.
compressor will cycle o and the fan will continue
to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it will not restart operation
for three minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
Check lter feature
The system starts to count the time once the fan
motor operates. The check lter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean lter indicator light) ashes at one time
per second, after nishing clean the air lter, press
the Filter pad and the Reset light(Clean lter indicator
light) goes o .
Auto-Restart
If the unit turns o unexpectedly due to a power outage,
it will restart with the previously set functions automatically
when the power resumes.
CONTROL PADS ON THE DEHUMIDIFIER
EC - Refrigerant leakage detection-- With this new technology,
the display area will appear EC when the unit detects
refrigerant leakage, call for service.
E3 - Unit malfunction-- Unplug the unit and plug it back in. If
error repeats, call for service.
Eb - Bucket is removed or not in right position-- Replace the
bucket in the right position.(only available for the unit with
pump feature.)
Setting the Timer
When the unit is on, rst press the Timer
button, the Timer O indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again and the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is o , rst press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again and the
Time O indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When the LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.