WINTER USE INSTRUCTIONS
• You can keep the spa on during winter when the temperature is lower than
42.8°F(6°C). The Freeze Shield™ system automatically keeps the water temperature
between 42.8°F(6°C) and 50°F(10°C), and it will prevent the water from freezing.
Important: If the water temperature is below 42.8°F(6°C), the spa heater must always
be on. In this mode, the Freeze Shield™ system can keep the internal temperature
between 42.8°F(6°C) and 50°F(10°C) to prevent damage, such as water freezing in the
pipes or the circulation system.
Important: If the Freeze Shield™ system isn't working, alarms will pop up on the spa.
Be sure to check the status of your spa if the outdoor temperature is below
42.8°F(6°C). In case of a long-term absence from home when there is a risk of
temperatures falling below 42.8°F(6°C), we strongly suggest disassembling the spa
and storing it following the storage procedure.
• Any damage as a result of using the spa in these conditions is the responsibility of the
customer. Do not use the spa when the ambient temperature reaches 14°F(-10°C).
HEATING RESET
When using the SALUSPA for first time, or after a long period of
inactivity, be sure to press the reset button on the pump using a
small and thin object.
If the temperature on the control panel (or the water temperature)
has not changed 4 hours - 5 hours after activation of the heating
system, use a thin object to press the RESET BUTTON, and restart the heating system.
IMPORTANT: The heating system will not operate if the outside temperature is above
104 ºF (40ºC) or if the SALUSPA is under direct sunlight. Under these conditions,
please wait until a cooler time of day before pressing the RESET BUTTON with a thin
object and restarting the heating system.
IMPORTANT
To reach 104°F(40°C), the heating duration required is based on the starting water
temperature and ambient temperature, the data below is purely for reference. To
display the current water temperature, run the filter system for at least a minute.
Ambient Temperature
50ºF(10ºC)
59ºF(15ºC)
68ºF(20ºC)
77ºF(25ºC)
86ºF(30ºC)
• Be sure to cover the spa with the spa
cover whenever the heating function is
activated. Leaving the spa uncovered
will increase the heating duration
required.
• When the spa is assembled with water,
do not switch off the spa heater if the
temperature is lower than 42.8°F(6ºC).
Power Rate
127 V ~ 60 Hz,
Single Phase
12A at 20ºC
Water Temperature
50ºF(10ºC)
59ºF(15ºC)
68ºF(20ºC)
77ºF(25ºC)
86ºF(30ºC)
Massage Tube Blower
6.5A
Set Temperature
104ºF(40ºC)
104ºF(40ºC)
104ºF(40ºC)
104ºF(40ºC)
104ºF(40ºC)
Heat Element
11.3A at 20ºC
14
Reset
Heating Duration
25.5 h
21 h
16 h
11.5 h
7.5 h
Water Pump
0.7A