OPERATING INSTRUCTIONS
en
32
O P E R A T I N G I N S T R U C T I O N S | WS/WE34
Switching current (switching voltage) I
Switching frequency
Response time
Enclosure rating
5)
Protection class
Circuit protection
Ambient temperature, operation
1)
Limit values; terminal connection: permissible wire cross-sections 0.14 to 1.5 mm
≤ 4 A
2)
Usage category: AC-15, DC-13 (EN 60947-1)
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
Pursuant to EN 60529
6)
Rated insulation voltage U
250 V AC, overvoltage category II
i
7)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
WS/WE34-B / -V -R
max.
1000 Hz
≤ 500 µs
IP67
II
6)
A, B, C
7)
–40 °C ... +60
°C
4 A @ 250 V AC,
4 A @ 24 V DC,
0.125 A @ 250 V
DC
2)
10 Hz
3)
3)
4)
≤ 10 ms
4)
IP67
II
6)
A, C
7)
–40 °C ... +60
°C
2
, male connector:
8009200.1DM8/2022-09-05 | SICK
Subject to change without notice