BTL5-S1_ _-M_ _ _ _-J-DEXA/B-K_ _
Micropulse Transducer - Rod Style
5
Startup
5.1
Check connections
Although the connections are po-
larity reversal protected, compo-
nents can be damaged by im-
proper connections and
overvoltage. Before you apply
power, check the connections
carefully.
5.2
Turning on the system
Note that the system may execute
uncontrolled movements when first
turned on or when the transducer
is part of a closed-loop system
whose parameters have not yet
been set. Therefore make sure that
no hazards could result from these
situations.
5.3
Check output values
After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end posi-
tion of the magnet in manual
mode. If values other* than those
present before the replacement or
repair are found, a correction
should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
6
Versions (indicated on product label)
Type: BTL5-S102-M0450-J-DEXA -K05
Supply voltage 1 = DC 24 V
example: BTL5-S102-M0450-J-DEXA-SA_ _ _-K05
Special version (optional, no effect on Ex properties)
10
english
5.4
Check functionality
The functionality of the transducer
system and all its associated
components should be regularly
checked and recorded.
5.5
Fault conditions
When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6 Maintenance
Cable 5 m, radial
Rod end: A = float stop
Rod style,
Mounting: 6 cylinder head screws
Nom. length (4-digit), M = metric, in mm
Resolution:
2 = 5 μm
Code:
24 Bit
0 = binär, steigend
2 = binär, fallend
25 Bit
6 = binär, steigend
8 = binär, fallend
B = short end
ISO 4762 – M6 × 22 – A2-70
3 = 10 μm 4 = 20 μm
5 = 40 μm
1 = Gray, steigend
3 = Gray, fallend
7 = Gray, steigend
9 = Gray, fallend
Flameproof enclosure
5.7 Repair
8 = 50 μm