Descargar Imprimir esta página

coralwai WAKE Manual De Instrucciones página 30

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLE SHOOTING
MALFUNCTIONING
Very little or no water flow
The osmosis unit
does not work
The water does
not taste normal
Noises during operation
of the osmosis unit
The osmosis unit
does not work.
FAULT Notice
POSSIBLE REASON
PE pipe is bent
The water source is closed
The water source is closed
The PP + C cartridge
is blocked
Low water pressure
Feed water temperature is
lower than the required
Electrical failure
Adapter loses efficiency
Machine with
insufficient water
Not in use for a long time
Poor water quality
Cartridges have not been
replaced for a long time
Power and voltage
do not agree
Low feed water flow
The adapter is damaged
Water pump failure
Lack of water inlet pressure
Unit running for 20
consecutive minutes
30
SOLUTIONS
Straighten the pipe
Open the water inlet valve
Wait for the source of supply to
Replace the cartridge
Increase the pressure
Increase feed
water temperature
Check the power supply
Replace the adapter
Check the feed water.
If the feed water is in good
condition, reconnect the
power supply
Rinse the cartridge for 5
minutes, if this does not solve
the problem, replace the
cartridge
Check the quality
of the feed water
Replace cartridges
Call a qualified person to have
it repaired
Increase the feed water flow
Call a qualified preofessional to
have it checked and repaired
Call a qualified preofessional to
have it checked and repaired
Check for water input, reset by
disconnecting and connecting
electrically
Reset by disconnecting
and connecting electrically