Descargar Imprimir esta página

Interlogix VE1012 Serie Instrucciones De Instalación página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
Put the appropriate mirror stickers if necessary. See
Figure 8, item 1 for details.
Caution:
Removing stickers can damage the mirror
surface.
When near objects directly under the detector, fit the mask
to the inside of the window (default). This disables the part
of the curtains looking down at the object, whose
closeness might destabilize the detector. See Figure 8,
item 2.
LED indication
Continuously on
Fast blinking (4 Hz)
PIR
Red LED
Alarm relay
Start up
Closed
Low voltage
Open (Alarm) Apply correct voltage
PIR intruder
Open (Alarm) Automatically after 3 s
alarm
PIR/AM
Red
Yellow
LED
LED
Start up
Low voltage
PIR intruder
alarm
Latched PIR
(Memory)
AM alarm
After AM
reset
Technical
fault
* Depends on the setting of the DIP switch SW4.
Specifications
Detector
Signal processing
Range
Optical
Memory
Input power
Peak-to-peak ripple
Detector start-up time
Normal current consumption
Current consumption in alarm
Maximum current consumption
Mounting height
Target speed range
P/N 146414999-2 (ML) • REV G • ISS 08MAR19
Normal blinking (1 Hz)
To reset
Automatically after 25 s
Alarm
AM
To reset
relay
relay
Closed
Closed
Automatically
after 60 s
Open
Open
Apply correct
(Alarm)
(Alarm)
voltage
Open
Automatically
(Alarm)
after 3 s
Switch to Night
mode
Open*
Open
See DIP
(Alarm)
(Alarm)
switch 3
Switch to
Night mode
Open
Do a successful
(Alarm)
walk test
VE1012
VE1012AM
PIR
PIR + AM
V2E
12 m (39 ft. 4 in.)
9 high-density mirror curtains
No
9 to 15 V
(12 V nominal)
2 V (at 12 V )
25 s
5.5 mA
10 mA
1.1 mA
3.8 mA
11 mA
24 mA
1.8 to 3.0 m
2.0 to 3.0 m
(5.9 to 9.8 ft.)
(6.6 to 9.8 ft.)
30 cm/s to 3 m/s
20 cm/s to 3 m/s
(1 ft./s to 10 ft./s)
(8 in./s to 10 ft./s)
Alarm (NC) / Tamper relay
characteristic
Pry-off tamper
AM relay characteristic
Alarm time
Operating temperature
Dimensions (H x W x D)
Relative humidity
Weight
IP/IK rating
Regulatory information
Manufacturer
Product warnings
and disclaimers
Certification
European Union
directives
Yes
Contact information
www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.utcfssecurityproducts.eu
60 s
VE1012
80 mA, 30 V
Optional
−10 to +55°C (14 to 130°F)
108 × 60 × 46 mm
(4.25 × 2.36 × 1.81 in.)
95% max.
120 g (4.2 oz.)
IP30 IK02
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY "AUTHORIZED
DEALER" OR "AUTHORIZED RESELLER", IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.utcfireandsecurity.com or
www.interlogix.com.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
VE1012AM
80 mA, 30 V
On-board (Yes)
80 mA at 30 V
max.
3 s
128 g (4.5 oz.)
5 of 26

Publicidad

loading

Este manual también es adecuado para:

Ve1012am