Installation
1
Preparing for installation
CAUTION: Always shut off the water supply before
removing an existing faucet or replacing any part of a
faucet. Open the faucet handle to relieve water pressure
and ensure that the water is completely shut off.
□
Shut off the water supply to the tub and
shower.
□
Verify that the hole sizes and positions of the
holes in the wall are correct:
□
The shower and tub spout outlet holes
should be 1-1/4 in. diameter.
□
For the cold water inlet (the right side)
and the hot water inlet (the left side),
cut or leave a 1-3/8 in. diameter hole
(recommended size is 1-3/4 in.). The
center to center distance between the
cold and hot water inlets is 8 in.
48 in.
Tub & Shower
30 in.
Shower Only
8 in. Min.
48 in.
Shower Only
30 in.
Tub & Shower
NOTE: Do not disassemble the cartridges during normal
installation. When reinstalling the cartridges, be sure to
insert with the cartridge slot (a & b) pointed outward as
shown in the diagram. This is necessary for proper
operation of the valve.
a
1-3/8 in. ~ 2 in.
1-3/8 in. ~ 2 in.
8 in.
b
2
Installing the supply
connections
NOTE: Be sure to position the valve body (D) correctly in
the wall, with the markings "UP" facing upward. Hot water
supply lines go into the "H" inlet; cold water supply lines
go into the "C" inlet.
□
Wrap thread sealant tape around the valve body
(D) threads in a clockwise direction, as shown.
□
Thread the waterline (1) to the valve body (D),
and tighten with a wrench.
Hot
7
Please contact 1-855-HD-GLACIER for further assistance.
D
Cold
HOMEDEPOT.COM/GLACIERBAY
1