Status
2 short tones
4 short tones
3.7 USB interface
The USB interface (type C, USB 2.0) can be used to connect
the torque module to a PC. When this connection is made, the
AT Documentation Software offers a range of functions, including:
Adding new data records for new fasteners
Changing / updating existing data records
Deactivating / activating the documentation function
Loading the log from the documentation function
Setting the clock in the torque module
Further information can be found in the documentation for the
AT Documentation Software.
The software can be downloaded from here:
http://www.hilti.com/adaptive_torque_documentation_software
3.8 Items supplied
Adaptive torque module, operating instructions, quick-start guide, USB
cable
Other system products approved for use with this product can be found at
your local Hilti Store or at: www.hilti.group
4
Technical data
Weight in accordance with EPTA proce-
dure 01
Laser class
6
English
Meaning
Warning tone 1
• OK or not OK, as applicable,
depending on the fastener and
the application (e.g.
torquing of a fastener, tightening
torque not detected. See the
section headed Tightening the
threaded fastener in "Adaptive"
operating mode)
• The LEDs flash yellow.
Warning tone 2
• Not OK
• Operation canceled
• The LEDs flash red.
0.24 kg