All manuals and user guides at all-guides.com
To Replace Regulator
1.
Release all air pressure from air tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Using an adjustable wrench remove the
outlet pressure gauge and quick connect
from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the nipple on the
standpipe.
6.
Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is
pointing in the direction of air flow.
7.
Reapply pipe sealant to outlet pressure gauge
and quick connect.
8.
Reassemble outlet pressure gauge and quick
connect. Orient outlet pressure gauge to read
correctly. Tighten connect with wrench.
D27856
Regulator
16 - ENG
Outlet
Pressure
Gauge
Quick
Connect
Nipple
Regulator
Regulator
Arrow