Descargar Imprimir esta página

Kohler K-45905 Guía De Instalación Y Cuidado página 9

Ocultar thumbs Ver también para K-45905:

Publicidad

Idiomas disponibles

Idiomas disponibles

Supply Adapter
Mounting Collar
2" (51 mm)
3. Mark the Mounting Hole Locations
NOTE: The upper mounting collar must be centered on the supply
adapter. The distance between the upper and lower mounting collar
centers should be 18" (457 mm) or 27" (686 mm) depending on the
length of your shower column.
Center the mounting collar on the supply adapter. Mark the left
and right mounting holes.
For K-45905 only: From the center of the supply adapter, measure
down 27" (686 mm) and mark the horizontal measurement with a
pencil.
For K-45906 only: From the center of the supply adapter, measure
down 18" (457 mm) and mark the horizontal measurement with a
pencil.
Center the mounting collar on the horizontal line. Measure and
mark the left and right mounting holes. Ensure the upper and
lower mounting hole locations are level and plumb to one
another.
Do not drill the mounting holes until instructed to do so.
Kohler Co.
K-45905
27" (686 mm)
K-45906
18" (457 mm)
Mounting Collar
9
1189046-2-B

Publicidad

loading

Este manual también es adecuado para:

K-45906