Descargar Imprimir esta página

Frigomat FR260 Manual De Uso Y Mantenimiento página 74

Publicidad

Idiomas disponibles

Idiomas disponibles

"MEB²" (**) BOARD PROGRAMMING TABLE
P
DESCRIPTION
P1
Machine model
P2
Slush coefficient
Consistency hysteresis
P3
(%of setting)
Voltage and frequency
P4
selection
Sampling 1 SET OK
P5
(AUTO cycle minimum
threshold)
Sampling 1 Time
P6
(AUTO cycle)
Sampling 2 SET OK
P7
(AUTO cycle average
threshold)
Sampling 2 Time
P8
(AUTO cycle)
Sampling 3 SET OK
P9
(AUTO HARD cycle minimum
threshold)
Sampling 3 Time
P10
(AUTO HARD cycle)
Sampling 4 SET OK
P11
(AUTO HARD cycle average
threshold)
Sampling 4 Time
P12
(AUTO HARD cycle)
P13
Not active
Beater ON time in Cyclic
P14
Slush mode
P15
Not active
P16
Not active
P17
Not active
35 - ENGLISH
MIN
MAX
T4S
0
7
5
10
40
15
1
50
10
0
2
*
50
200
150
0
22
10
50
200
190
0
22
4
50
200
180
0
22
14
50
200
200
0
22
10
STEP
T4S=5
T5S=6
1
1
0= 115-230/50-60/1
1= 400-440/50-60/3
2= 220/230/50-60/3 (without
neutral)
1
4,5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.
1
4,5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.
1
4,5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.
1
4,5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.

Publicidad