Descargar Imprimir esta página

UFESA AC2500 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
10
Sliding the slider according to the marking (MAX
or MIN) will cause the suction power to increase or
decrease.
Filter disassembly
Before you replace the filters, make sure the vacuum
has been switched off and the plug is removed from
the power outlet.
INLET FILTER
1
Press the two side buttons located on the hose
end and remove the ending of the hose from the outlet
opening.
2
Release the front cover interlock (7) and open it.
3
Tilt bag' s handle and remove the bag.
4
Pull the inlet filter out of the compartment (14).
5
Attach the new inlet filter (14).
6
Insert the bag' s plate between rails and slip it along
with the screen down until it reaches the bottom of the
container, unfold the bag. Follow the arrow indicating
the direction of unfolding the bag.
7
Close the lid by pushing it until you hear the click –
be careful not to shut the bag.
Damaged inlet filter should always be
replaced with a factory new and original
item.
It is recommended to replace the inlet
filter every 4 replacements of SAFBAG
or more often if the filter is very dirty.
OUTLET FILTER
1
Press the interlock on the outlet filter cover and
remove the shield from from the vacuum cleaner.
2
Remove used filter.
3
Attach the new filter making sure that the new one
is positioned correctly.
4
Pull back and close the filter cover – the clip should
be locked. The click you hear confirms that the outlet
filter cover has been correctly attached.
Damaged outlet filter should always be
replaced with a factory new and original
item.
SAFBAG dismantling/fitting
1
When the bag filling indicator is completely covered
by a red screen when the nozzle or brush is raised over
the cleaned surface, it means that it is necessary replace
the bag. Bag filling indicator may also be triggered if the
suction hose or the elements connected to it are clogged.
2
Switch the vacuum off by pressing ON/OFF
button (1).
3
Remove the plug from the power outlet.
C
4
Press the two side buttons located on the hose end and
remove the ending of the hose from the outlet opening.
5
Release the front cover interlock (7) and open it.
6
Tilt bag' s handle and remove the bag.
7
Insert the new bag' s plate between the rails and
slip it along with the screen down until it reaches the
bottom of the compartment, unfold the bag. Follow the
arrow indicating the direction of unfolding the bag.
8
Close the lid by pushing it until you hear the click –
be careful not to shut the bag.
Do not vacuum when the SAFBAG is not
attached.
You are recommended to replace the bag, if you notice
that:
a) safety valve has been triggered,
b) your vacuum cleaner is vacuuming less effectively,
c) bag is full.
The number of new SAFBAG dust bags that should be
bought is provided on the stick placed on the vacuum' s
compartment.
End of operation, cleaning and
maintenance
D
1
Switch the vacuum off by pressing ON/OFF
button (1).
2
Remove the plug from the power outlet.
3
Wind the cord by pressing cord rewind button (3).
While doing it, remember to hold the cord to make sure
it does not get tangled and the plug does not hit the
vacuum' s hosing.
4
Disconnect the suction tube and the nozzle or the
brush.
5
Disconnect the suction tube from the hose. In order
to remove the telescopic handle from the hose handle,
press latch "A" and pull the tube towards the arrow.
E
F

Publicidad

loading