FUNCTIONAL DESCRIPTION
WARNING:
Always be sure that the tool is switched off
and battery cartridge is removed before
adjusting or checking function on the tool.
Failure to switch off and remove the battery
cartridge may result in serious personal injury from
accidental start-up.
Installing or removing battery cartridge
CAUTION:
Hold the tool and the battery cartridge firmly
when installing or removing battery cartridge.
Failure to hold the tool and the battery cartridge
firmly may cause them to slip off your hands and
result in damage to the tool and battery cartridge
and a personal injury.
Always switch off the tool before installing or
removing the battery cartridge.
3
012391
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip
it into place. Always insert it all the way until it locks in
place with a little click. If you can see the red indicator
on the upper side of the button, it is not locked
completely. Install it fully until the red indicator cannot
be seen. If not, it may accidentally fall out of the tool,
causing injury to you or someone around you.
NOTE:
Do not use force when installing the battery
cartridge. If the cartridge does not slide in easily, it
is not being inserted correctly.
1. Red indicator
2. Button
3. Battery
cartridge
1
2
Battery protection system
(Lithium-ion battery with star marking)
1
012128
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically cuts
off power to the tool to extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the trigger switch on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
trigger switch again to restart.
If the tool does not start, the battery is
overheated. In this situation, let the battery
cool before pulling the trigger switch again.
Low battery voltage:
The remaining battery capacity is too low
and the tool will not operate. In this situation,
remove and recharge the battery.
Power switch action
WARNING:
Before inserting the battery cartridge in the
tool, always check to see that the switch
trigger actuates properly and returns to the
"OFF" position when released. Do not pull the
switch trigger hard without pressing in the
lock-off
button.
breakage. Operating a tool with a switch that does
not actuate properly can lead to loss of control and
serious personal injury.
1
012397
7
1. Star marking
This
can
cause
1. Lock-off button
2. Switch trigger
2
switch

Publicidad

loading

Este manual también es adecuado para:

Xru02