User Manual
MONITOR 2
LINE
EXAMPLE
(1)
43,3V 35A
(2)
(3)
7Ah PhI1 13m22s
(4)
-- Message
MONITOR 3
LINE
EXAMPLE
(1)
N.CYCLE=
(2)
C1ID=1PB ST_01.0001
(3)
Vbif=1.68V/el = 40.4V
(4)
Vbef=1.81V/el = 43.4V
(5)
Ibif= 36A Ibef= 35A
(6)
Tf =0h13m Tef=0h13m
(7)
Ahf= 7 AhEf= 7
(8)
-- Message
GUARANTEE
• The machine is guaranteed 12 months from the date of
installation.
• The
guarantee
manufacturing or assembly.
• The guarantee does NOT cover damage caused by incorrect
usage and/or installation.
• The guarantee lapses if any tampering is discovered.
• For any problems, please refer to an AUTHORISED RETAILER
or directly to S.P.E. Elettronica Industriale
24
7 – Ph 1
covers
DESCRIPTION
Battery Voltage and Current Supplied
Active charge profile with indication:
Phases complete (thick line)
Phase in progress (flashing line)
Phases to execute (thin line)
Ah charged, Charging time in hours, min, sec
Possible fault or status messages
DESCRIPTION
Number of charge cycle and current charge phase
E.g. : charge cycle 5 and Phase 3
Charging curve unique identification
Battery voltage at start of phase (Vbif) expressed
first as element voltage (V/el), then as absolute
voltage (V)
Battery voltage at end of phase (current) (Vbef)
expressed first as element voltage (V/el), then as
absolute voltage (V)
Current at start of phase (Ibif) and current at end of
phase (Ibef)
Single phase time (Tf) and Overall charge time at
end of phase (Tef)
Ah supplied in the selected phase (Ahf) and overall
charge Ah (AhEf)
Indicates any faults occurring during the charge
cycle
parts
found
to
be
defective
in
D00582-08