MAINTENANCE
MAINTENANCE
CHECK
Throttle cable for adjustment
Mower deck for adjustment
Condition of belts, belt pulleys
Caster wheels (at 200 hour intervals)
Engine valve clearance
CHANGE
Spark plugs
1)
Engine oil
Engine oil filter
Fuel filter
2)
Paper air filter
Air cleaner foam pre-filter
ALSO
Do the 300-hour service
= Described in this manual
= Not described in this manual
= Refer to the engine manufacturer's manual
1)
First change after 8-10 hours. When
operating with a heavy load or at high ambient
temperatures, replace at 50 hour intervals.
2)
In dusty conditions, cleaning and replacement
are required more frequently.
3)
Performed by authorized service workshop.
4)
If equipped.
IMPORTANT INFORMATION The mower is
equipped with a 12-volt negative grounded
system. The other vehicle must also be a
12-volt negative grounded system. Do not use
your mower to start other vehicles.
CAUTION! Always wear eye
protection when around batteries.
BEFORE
3)
2) 4)
3)
AT LEAST
DAILY
ONCE
EACH
AFTER
YEAR
WARNING! Some replacement batteries
may differ from OEM battery. Always ensure
the RED battery cable is connected to the
positive (+) battery terminal and the BLACK
cable is connected to the negative (-) battery
terminal.
WARNING! Do not short battery
terminals by allowing a wrench or other objects
to contact both terminals at the same time.
Before connecting battery, remove metal
bracelets, wristwatch bands, rings, etc.
Positive terminal must be connected first to
prevent sparks from accidental grounding.
IMPORTANT INFORMATION Before
restarting the unit, be sure to replace guards
that have been removed for maintence.
MAINTENANCE INTERVAL
IN HOURS
25
50
100
300