Incorrect installation
The outlet pipe (15) should not be excessively bent – drawing 5.
Improper installation can result in the improper operation of the device.
There must be no sharp bends in the outlet pipe (15).
The air leaving the unit must flow freely.
NOTE
The length of the outlet pipe (15) is designed in accordance with the air conditioner's
specifications. Do not replace the outlet pipe with other hoses, or extend it, as this can
cause malfunction of the unit. The maximum length of the straightened outlet pipe
is 1500 mm. Use the shortest pipe length possible. It is most recommended to install
the outlet pipe horizontally.
TIPS
In order to reach the target temperature as soon as possible during the cooling process,
the doors and windows in the air-conditioned room should be closed, and the use of heat-
emitting devices should be kept to a minimum.
Do not expose yourself to cold air for long periods of time, as this is harmful to your
health.
THE CONTROL PANEL, REMOTE CONTROL – drawing 1.
A
TIMER - used to start and stop the automatic operation of the device.
B,C buttons
-
for
Pressing both buttons on the control panel simultaneously changes the temperature
units between Fahrenheit and Celsius degrees.
D
fan-speed selection (F2 = fast, F1 = slow).
E
selecting the operating mode (
F
switching the device on/off.
G
display.
H
REMOTE CONTROL - switching the night mode on/off.
THE OPERATION OF THE APPLIANCE
All changes in the settings are confirmed with a sound signal.
The air flow from the air conditioner should not be directed directly at people.
The cold air flow can be controlled by means of the louvres (3).
COOLING
Switch on the device with the „F" button.
Press the „E" button - cooling is indicated by the
The display „G" shows the temperature pre-set within the range 16°C to 31°C.
Use the „B" and „C" buttons to set the temperature.
The fan speed can be set by pressing the „D" button.
When using the dehumidification mode, the pipe discharging the air to the outside must
be connected to the unit to.
setting
the
temperature
- cooling,
(cooling)
and
- dehumidification,
indicator light.
(TIMER).
time
- fan).
•
EN
21