2-4. Outer Dimensions of Outdoor Unit
A
Diagram of Outdoor Unit Installation
2-5.
Never install only a single indoor unit.
Ensure 15cm
of space if a
drain hose is to
be used.
Base (not provided)
(concrete or similar material)
A
Be sure to connect indoor and outdoor units only in
combinations that are listed in the catalog or in the
combination table that was provided with the outdoor unit.
(Use caution. Connecting any other model may result in
operation failure and malfunction.)
The dimensions indicated by
in the figure below are
spaces that are required in order to maintain
performance. Install in a location where the dimensions
indicated by
are ensured, and where 2 or more faces
of the unit are unobstructed. In principle, the top direction
should be unobstructed.
Fasten with anchor bolts
(not provided)
(3/8" or M10, 4 locations)
940
80
Fig. 6a
Leakage breaker
/fuse link
E
D
C
B
A
Ground
wire
(not
provided)
Fig. 6b
10
Service valve on wide tube side
(Outer diameter
Service valve on narrow tube side
(Outer diameter
51
110
Service valve on wide tube side
(Outer diameter
Indoor unit E
Indoor unit D
Indoor unit C
Indoor unit B
Indoor unit A
Service space
Terminal cover
Access panel C
12.70)
6.35)
9.52)
unit: mm