The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the
gas part and with norm
in force particularly concerning room ventilation and discharging gas emissions.
N.B.: The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect
installation, alterations, maintenance or use of the appliance, as in all the other cases considered in the items of our sales
conditions.
DIMENS
MODEL
cm
TP-74G
40x70x90h
TP2-78GP
80x70x90h
TPF2-78GP
80x70x90h
80x70x90h
TPF2-78GPE
80x70x90h
TPFV2-78GPE
TP4-712GP
120x70x90h
120x70x90h
TPF4-712GPV
TPF4-712GP
120x70x90h
120x70x90h
TPF4-712GPEV
TPFV4-712GPEV
120x70x90h
TPF4-712GPE
120x70x90h
40x70x29h
TPT-74G
TP2T-78GP
80x70x29h
120x70x29h
TP4T-712GP
DIMENS.
MODEL
cm
80x70x29h
TPF2-78GPE
TPF4-712GPEV
120x70x90h
120x70x90h
TPF4-712GPE
TPFV2-78GPE
80x70x29h
80x70x29h
TPFV2-78GPE
TPFV4-712GPEV
120x70x90h
120x70x90h
TPFV4-712GPEV
•
The operations for installing, conversions for use with other types of gas and starting up must be done only by
qualified personnel whose qualifications comply with the norms in force.
•
Gas installations, the electrical connections and the rooms in which the appliances are installed must comply with
the norms in force in the Country in which the installation is carried out; above all, the appliance must be installed
in a well ventilated room, preferably under an extractor hood, so as to ensure the complete extraction of gas
emissions which are formed during combustion. The air necessary for combustion is 2m3 /h per kW of power
installed.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.
DECLARATION OF COMPLIANCE
for the electric part. The installation must be done observing the norms
2006/95/CE,
2004/108/CE
GAS TECHNICAL DATA TABLE
OPEN
TP
RING
BURNER
BURNER
7 kW
7,5 kW
1
/
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
/
1
1
1
1
ELECTRIC TECHNICAL DATA TABLE
POWER SUPPLY
400Vac3N 50/60 Hz
400Vac3N 50/60 Hz
400Vac3N 50/60 Hz
400Vac3N 50/60 Hz
230Vac3 50/60 Hz
400Vac3N 50/60 Hz
230Vac3 50/60 Hz
INSTALLATION
CHECKING FOR CORRECT VENTILATION
GB
IE
IT
CH
OPEN
OPEN
RING
RING
BURNER
BURNER
5,5 kW
3,5 kW
/
/
1
/
1
/
1
/
1
/
2
1
2
1
2
1
2
1
2
1
2
1
/
/
1
/
2
1
MAXIMUM
MAXIMUM
ABSORPTION A
POWER kW
10,4
10,4
10,4
8,06
5,32
13,35
5,32
8,06
5,32
13,35
5,32
43
TOTAL
OVEN
OVEN
POWER
BURNER
BURNER
7,3 kW
11 kW
/
/
/
/
1
/
/
/
/
/
/
/
1
/
/
1
/
/
/
/
/
/
/
/
/
/
/
/
Emissivity
dB(A)
5
/
5
/
6,9
/
<70
<70
<70
<70
GAS
CONNECTIO
(kW)
N
ISO 7-1
7
R1/2GM
R1/2GM
20
3/4GM(1007)
27,3
R3/4GM
R1/2GM
20
3/4GM(1007)
20
R3/4GM
29
R3/4GM
36,3
R3/4GM
40
R3/4GM
29
R3/4GM
29
R3/4GM
29
R3/4GM
7
R1/2GM
20
R1/2GM
29
R3/4GM
POWER SUPPLY
CABLE (Silicon)
5x1,5
5x1,5
5x1,5
5x1,5
4x1,5
5x1,5
4x1,5