1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.1 N
-D
I
ON
UCTED
NSTALLATION
For a non-ducted installation, we recommend using interior blower Best model iQ6, P3 or P6 for effectiveness. (Blower sold
separately.)
The non-duct kit ANKWP Series (sold separately) must be installed. This kit fits hood from 30-inch width up to 48-inch width. See
installation instructions included with the non-duct kit ANKWP Series.
1.2 D
I
UCTED
NSTALLATION
For a ducted installation, either an interior or exterior blower or in-line blower may be used with this hood. The Best WP29M Series
must be installed with blower models iQ6, P3, P6, iQ12, P12, ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 only.
Other blowers cannot be substituted. (Blowers sold separately.)
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1 up to 8, 11, 12, 15 and up of this
manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. Use metal duct tape to seal duct
joints.
NOTE: It is recommended that there be a minimum of 6" of straight duct from this hood to an elbow for 8" ducting and 12" for 10" ducting.
DECORATIVE
FLUE
SOFFIT
OR
HOOD
24 " TO 36 "
ABOVE COOKING SURFACE
HH0205A
MODEL iQ6, P3 OR P6
SINGLE INTERIOR BLOWER
TYPICAL DUCTWORK
DECORATIVE FLUE
SOFFIT
OR
HOOD
24" TO 36" ABOVE
COOKING SURFACE
HH0207A
MODEL EB6, EB9, EB12 OR EB15
EXTERIOR BLOWER TYPICAL DUCTWORK
ROOF CAP
8 " ROUND DUCT
6 "
OR
12 "
WALL CAP
EXTERIOR BLOWER
10" ROUND DUCT
6"
OR
EXTERIOR
12"
BLOWER
DECORATIVE
FLUE
SOFFIT
OR
HOOD
24" TO 36" ABOVE
COOKING SURFACE
HH0206A
MODEL iQ12 OR P12
DUAL INTERIOR BLOWER
TYPICAL DUCTWORK
10" ROUND DUCT
(
HLB3, 8" ROUND DUCT)
EXCEPT
IN-LINE BLOWER
24" TO 36" ABOVE
COOKING SURFACE
HH0208A
MODEL ILB3, ILB6, ILB9 OR ILB11
IN-LINE BLOWER TYPICAL DUCTWORK
5
ROOF
CAP
10" ROUND DUCT
6"
OR
12"
WALL
CAP
ROOF CAP
WALL
CAP
HOOD